排煙風機(ji)常見(jian)問題解決方(fang)法
3C排煙(yan)風(feng)機(ji)廠家操(cao)作注意事項:運轉(zhuan)(zhuan)設(she)(she)備(bei)轉(zhuan)(zhuan)動部(bu)分必須有(you)安(an)全防護罩。突然停(ting)(ting)電(dian)(dian)時,循環水泵(beng)停(ting)(ting)止(zhi)連(lian)轉(zhuan)(zhuan),必須馬(ma)上通知煉焦車間與有(you)關(guan)部(bu)門(men),關(guan)閉氨水泵(beng)出口。機(ji)電(dian)(dian)設(she)(she)備(bei)運轉(zhuan)(zhuan)時,不準拆卸,危險部(bu)位(wei)不準擦拭。生產區域內嚴禁(jin)(jin)煙(yan)火,必須動火處理時,需辦理動火手(shou)續,并有(you)安(an)全措(cuo)施和監火人,經有(you)關(guan)部(bu)門(men)批(pi)準后方可(ke)(ke)動火。停(ting)(ting)車后要對設(she)(she)備(bei),管道進(jin)(jin)行清掃,放空,嚴禁(jin)(jin)違章操(cao)作。嚴禁(jin)(jin)循環水帶焦油操(cao)作,要班班倒壓焦油。在(zai)進(jin)(jin)行設(she)(she)備(bei)的控(kong)負載試電(dian)(dian)工作之前(qian),電(dian)(dian)工確認設(she)(she)備(bei)接(jie)地可(ke)(ke)靠。不準用(yong)溫布(bu)擦試運行電(dian)(dian)機(ji)和電(dian)(dian)器(qi)開關(guan),且(qie)40KW以上的電(dian)(dian)機(ji)不準連(lian)續啟動三次。
3C排煙風機廠家(jia)殼(ke)(ke)體無(wu)嚴重變形、開裂,各(ge)零部(bu)件(jian)齊全(quan)、完(wan)整。機(ji)體外表除銹干凈,刷(shua)漆均勻,無(wu)溢(yi)流(liu)起泡、脫(tuo)皮現(xian)象(xiang),螺(luo)(luo)母擰緊后,螺(luo)(luo)栓的(de)螺(luo)(luo)紋應(ying)露(lu)(lu)出(chu)螺(luo)(luo)母1~3個螺(luo)(luo)距,不得在螺(luo)(luo)母下面加多余的(de)墊圈來減少螺(luo)(luo)栓的(de)露(lu)(lu)出(chu)長度,葉輪應(ying)按照(zhao)規定裝配應(ying)牢(lao)固(gu)可(ke)靠,無(wu)缺葉、無(wu)裂紋、無(wu)磨殼(ke)(ke)體現(xian)象(xiang)。
密(mi)封膠(jiao)(jiao)圈外徑(jing)(jing)與(yu)進(jin)線裝置內徑(jing)(jing)間(jian)隙應符合(he)(he)(he):密(mi)封膠(jiao)(jiao)圈外徑(jing)(jing)大于(yu)(yu)等于(yu)(yu)20mm時(shi),配(pei)合(he)(he)(he)間(jian)隙小于(yu)(yu)等于(yu)(yu)1.0mm。密(mi)封膠(jiao)(jiao)圈外徑(jing)(jing)大于(yu)(yu)20mm小于(yu)(yu)60mm時(shi),配(pei)合(he)(he)(he)間(jian)隙小于(yu)(yu)等于(yu)(yu)1.5mm,密(mi)封膠(jiao)(jiao)圈外徑(jing)(jing)大于(yu)(yu)60mm時(shi),配(pei)合(he)(he)(he)間(jian)隙小于(yu)(yu)等于(yu)(yu)2m
========================================
凱億網宣辦:紀 2021.10.04 報價電話:15806889279
========================================